Processing

Marine flame(protect compact

Fire protection panel with low flame-spread characteristics, consisting primarily of mineral components. With a white core and decorative melamine resin surfaces on both sides.

Field of application

  • Suitable for universal use in fire prevention to reduce the fire load, especially where there is a particular requirement for design and user-friendliness. Possible applications for ship building interiors including furniture, fittings and wall coverings in halls, corridors and stairwells. The material is not suitable for wet areas or outside use.

Downloads

Marine products

847.92 kB | Download pdf

Marine flame(protect compact

Sizes in mm Thickness in mm Textures
Length Width
2,750 2,020 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 47 | 49

Core material

  • Non-combustible compact core
  • Compact core with excellent strength properties, consisting primarily of mineral components.

Density

  • 1,900 kg/m³ ± 50 kg/m³ (ISO 1183)

Marine Classification

  • Low Flame-Spread Surface Material (MED)
  • Low Flame-Spread Surface Material (US Coast Guard)
  • Low Flame Spread Surface Linings (Transport Canada)

Formaldehyde emission class

  • E1 (EN 717-1)

Chemical resistance

  • Resistant to organic solvents, weak acids, petrol and oil.

Cleaning and care

  • The surface can be cleaned with water and gentle cleaning agents. To remove stubborn stains, please observe the recommendations in the data sheet "Cleaning of HPL surfaces".

Product safety

  • The surface is physiologically safe, and approved for direct contact with food.
  • The decorative coating consists of printed or dyed décor papers. They are saturated in the duroplast melamine-formaldehyde resin, which then hardens during the laminating process to form a highly resistant, non-reactive material.
  • We manufacture the panels without the use of halogens, heavy metals, preservatives, wood protectors or organic solvents.
  • This product is following the REACH regulation EG 1907/2006 an article. Following Article 7 it needs not to be registered.
  • The material is not rated as hazardous material.

Special

  • Other textures on request.
  • The colour may differ slightly from HPL with overlay.
  • Specially with light designs slight colour variations to other procucts are possible. Please contact us if a combination of these materials is required.
  • The application for hoizontal and abrasional heavy used areas depends on the design. You can find further details in the technical data sheet.

Downloads

Technical details

468.74 kB | Download pdf

Cleaning of HPL surfaces

74.03 kB | Download pdf

Marine flame(protect compact

Certificates

MED & US Coast Guard - Type Approval

862.50 kB | Download pdf

Transport Canada - Type Approval Certificate

782.50 kB | Download pdf

MED & US Coast Guard - Quality System Approval, Module D

79.51 kB | Download pdf

Certificate of compliance: Proove of food harmless

1.08 MB | Download pdf

Marine flame(protect compact

Machines and tools

  • Machining can be done on all common machining equipment and processing centres.
  • Diamond tipped tools are suitable for machining and processing.

Edging

  • It is generally recommended to seal the edges.
  • PUR hotmelts are recommended for edge adhesion.

Fitting technology

  • All conventional removable and non-removable fittings for wood materials, compact laminates and mineral boards are suitable.

Installation and assembly

  • Sufficient conditioning is required prior to installation. The premises themselves need to be air-conditioned according to the future use. Once installed a good rear ventilation as well as well a balanced climate must be ensured.
  • The fixing of the boards to the underground always needs to be done mechanical with non-combustible fixing material.
  • Ensure that there is an adequate area of “play” for the panel after installation; drill holes should be over-sized by a minimum of 0.5 mm.
  • Please ensure that the material is processed and fitted correctly and using the best available technology.

Health and safety

  • Provide adequate extraction when splitting/grinding.
  • Provide adequate ventilation and fresh air supply.
  • Prevent dust from settling, or remove regularly.
  • Suck (vacuum) dust when cleaning; do not blow.
  • Work clothes should cover the body entirely (trunk, legs and arms) whilst processing these panels.
  • Use the usual products for skin protection (creams etc.).
  • We advise operators to wear a face mask (P2).

Storage and handling

  • On all level surfaces (e.g. pallets), in dry, vented rooms.
  • Protect from moisture and wet conditions.

Disposal

  • When machining large quantities, we advice using a separate saw dust extraction. Offcuts and large amounts of saw dust are to be collect and disposed of separately.
  • Waste code for disposal: 030199